Fire Suppression Systems · Houston, Texas
Technical supportsupport@duenorthfire.com
Documents
Home / Systems
Suppression systems

Engineered around the hazard.

Every DueNorth system is an engineered system, individually calculated using approved system components within controlled design parameters. Agent selection, agent quantity, pipe network, and nozzle placement are determined for the specific enclosure being protected, not taken from a catalog. The DueNorth portfolio is structured around engineered system families matched to the hazard and project requirements.

The portfolio

Engineered systems, one design discipline.

Each family is sold as a complete engineered system. Components are configured within the system for the protected space; they are never specified or sold on their own.

Clean agent
FK-5-1-12 Clean Agent Systems
DN5112 · Engineered total flooding system
DN5112 single-cylinder FK-5-1-12 clean agent system rendering

An engineered clean agent system for enclosures where water or conventional agents would cause unacceptable damage or downtime. The agent is electrically non-conductive, leaves no residue after discharge, and may be used in normally occupied spaces when the design concentration and personnel-exposure provisions comply with NFPA 2001.

FK-5-1-12 Total flooding NFPA 2001
Listings & approvals
Stated per product in the technical documentation on the system page.

Availability is subject to completion of applicable certification and product-release requirements.

Choosing a technology

Choosing the right suppression technology

System selection depends on the hazard, enclosure characteristics, equipment sensitivity, available space, project requirements, and applicable approvals.

Compare suppression technologies

Releasing & control interface
Actuated by listed releasing control equipment.

DueNorth suppression systems interface with compatible listed releasing control equipment in accordance with the applicable design and installation requirements. Detection, releasing, notification, and supervisory functions are provided by a listed releasing control unit, installed in accordance with its listing and the requirements of the Authority Having Jurisdiction.

Interface guidance only, not a separate DueNorth product family.
Technical documentation
Design data, organized by document number.

System design and installation manuals, data sheets, specifications, and per-product listing and approval status are maintained in the controlled document library. Current revisions live in one location.

Open the document library
Bring us the enclosure.
Send the space, its contents, and the hazard, and we will help you determine the right family and route you to the design data your submittal needs.